Which electrode for which Titration, Application Bulletin Metrohm

Which electrode for which Titration?

Titrant
Specifics
Electrode description*
Cat. No./
Order No.
Reference Electrolyte
Remarks

Aqueous acid/bases

Combined LL pH glass electrode

020912146
(6.0232.100)

c(KCl) = 3 mol/L

020096101
(6.2308.020)

alkaline samples

Combined LL pH glass electrode, U glass

020912162
(6.0222.100)

c(KCl) = 3 mol/L

020096101
(6.2308.020)

titrations performed at high temperatures

Unitrode

020910674
(6.0259.100)

c(KCl) = 3 mol/L

020096101
(6.2308.020)

titrations with small sample volumes

Combined LL micro pH glass electrode
OR
Combined flat membrane pH glass electrode

020912235
(6.0234.100)

020915617 (6.0227.100)

c(KCl) = 3 mol/L

020096101
(6.2308.020)

Shaft diameter 6.4 mm, minimal immersion depth; 10 mm

Shaft diameter 12 mm, minimal immersion depth; 1–2 mm

titrations in water with low conductivity

Aquatrode plus

020910631
(6.0252.300)

c(KCl) = 3 mol/L

020096101
(6.2308.020)

Typical application: water analysis - p&m value etc.

Perchloric acid

See AB 80 and Monograph"Non-aqueous titration of acids and bases with potentiometric endpoint indication"

Solvotrode - combined LL pH glass electrode, ground-joint diaphragm (PCTFE)

020910551
(6.0229.100)

c(LiCl) = 2 mol/L in Ethanol

020094435
(6.2312.010)

easy to clean sleeve diaphragm

IMPORTANT: When not in daily use, store in LiCI sat. in ethanol and soak membrane in distilled water before use. However, when in daily use, store in distilled water, so that only the membrane is immersed, not the diaphragm. Before the measurement lift the diaphragm sleeve slightly and allow a small amount of electrolyte to flow out. Rinse the electrode with distilled water, replenish the reference electrolyte and start the titration (see bottom of chart).

IMPORTANT: Never fill the Solvotrode with LiCIO4 in glacial acetic acid!

TBAOH

See AB 80 and Monograph"Non-aqueous titration of acids and bases with potentiometric endpoint indication"

Solvotrode - combined LL pH glass electrode, ground-joint diaphragm (PCTFE)

020910551
(6.0229.100)

c(TEABr) = 0.4 mol/L in ethylen glycol1

020094451
(6.2320.000)

Potassium methylate

Solvotrode - combined LL pH glass electrode, ground-joint diaphragm (PCTFE)

020910551
(6.0229.100)

c(TEABr) = 0.4 mol/L in ethylen glycol1

020094451
(6.2320.000)

Cyclohexyl-amine

Solvotrode - combined LL pH glass electrode, ground-joint diaphragm (PCTFE)

020910551
(6.0229.100)

saturated LiCl in Ethanol

020094443
(6.2312.000)

Silver nitrate

AB 25

Ag-Titrode, possibly Ag2S coated

6.0430.100

Electrode is also available with a plug-in head S: 20 94 852-3 (6.0430.500)3

arsenite, cerium sulphate, iron (III), iodine, potassium bromate, sodium nitrite, sodium thiosulphate, oxalic acid, permanganate, titanium

For titrations where the pH value during the titration doesn't change.

Pt-Titrode

6.0431.100

Electrode is also available with a plug-in head S: 20 94 852-3 (6.0431.500)3

For titrations during which the pH value changes.

Combined LL Pt-ring electrode

6.0451.100

c(KCl) = 3 mol/L

020096101
(6.2308.020)

Karl-Fisher reagent

Double Pt-wire electrode

020928841
(6.0338.100)

Cr3+ , Fe2+,

Also for COD titrations

Micro Au-Titrode

020948604
(6.0435.110)

L = 160 mm, Loger version available: (6.9904.023), L= 250 mm

EDTA

Back-titration of the BaCl2 excess. For sulphate determination see AB 140.

Polymer membrane electrode, Ca2+

020955856
(6.0508.110)

c(KCl) = 3 mol/L

020096101
(6.2308.020)

a separate reference electrode is needed. Order no: 20 94 411-1 (6.0726.107)

EDTA

Complexon® III and IV

Determination of Al, Ba, Ca, Cd, Bi, Co, Fe, Mg, Ni, Pb, Zn. See AB 125

Ion selective electrode Cu2+

020959002
(6.0502.140)

c(KCl) = 3 mol/L

020096101
(6.2308.020)

a separate reference electrode is needed. Order no: 20 94 411-1 (6.0726.107)

Determination of Ca, Mg, See AB 125

Polymer membrane electrode, Ca2+

020955856
(6.0508.110)

Surfactants in aqueous media

Tego® trant A 100,2
see AB 233

Ionic surfactant electrode

020959321
(6.0507.120)

c(KCl) = 3 mol/L

020096101
(6.2308.020)

a separate reference electrode is needed. Order Nr: 6.0726.100

sodium lauryl sulphate, see AB 233

Ionic surfactant electrode
020959321
(6.0507.120)

c(KCl) = 3 mol/L

020096101
(6.2308.020)

a separate reference electrode is needed. Order Nr: 6.0726.100

Sodium tetra phenyl borate, see AB 230, AB 263

NIO surfactant electrode

020959304
(6.0507.010)

Inner chamber of the reference electrode:
c(KCI) = 3 mol/L 020096101 (6.2308.020) Outer chamber: c(NaCL) = 1 mol/L

a separate reference electrode is needed. Order Nr: 6.0726.107

Non aqueous surfactants

Nonaqueous media, solvents as Chloroform, MIKB, see AB 269

Surfactrode resistant

020959312
(6.0507.130)

c(KCl) = 3 mol/L

020096101
(6.2308.020)

a separate reference electrode is needed. Order no: 20 94 411-1 (6.0726.107)

electrode not suitable for high salt concentrations and pH > 10

Nonaqueous media, solvents as MIKB

Two phase titration, see AB 269

Surfactrode refill

020959339
(6.0507.140)

c(KCl) = 3 mol/L

020096101
(6.2308.020)

a separate reference electrode is needed. Order no: 20 94 411-1 (6.0726.107)

electrode not suitable for Chloroform

AB = Application Bulletin

* All these electodes are equipped with a Metrohm plub-in head G3

1 TEABr 0.4 mol/L tetra ethyl ammonium bromide in ethylene glycol (020094451) is an electrolyte solution for non-aqueous titrations. It is very useful when titrating low acid contents with TBAOH. In such cases the 2 mol/L LiCI in ethanol (020094435) would cause an alkali error during the measurement. The Solvotrode is a combined pH glass electrode specially designed for non-aqueous titrations. This electrode is normally filled with LiCI sat. in ethanol. However, when titrating with TBAOH we strongly recommend replacing the CiCI electrolyte with 0.4 mol/L TEABr in ethylene glycol. This electrolyte can of course also be used for all other non-aqueous titrations with various titrants.

2 TEGO trant A 100
020959274 (6.2317.000) (6 g)
020959282 (6.2317.010) (60 g)
Available on request 6.2317.020 (500 g)

3 To connect an electrode with plug-in head G to a Titrino or 726/796 Titroprocessor, use one of the following cables: 020977345 (1 m) or 020977353 (3 m). See Metrosensor Electrode Catalog for additional information.

Storage of the Solvotrode when not in daily use: Store the Solvotrode in 2 mol/L LiCI in ethanol. Use a normal Electrode holder.